SpikeInterface 0.96.1 release notesΒΆ
27th October 2022
- Main change:
Bump up probeinterface version to version 0.2.14 due to bug fix in reading SpikeGLX electrode locations https://probeinterface.readthedocs.io/en/main/releases/0.2.14.html
Warning
Probeinterface v0.2.14 fixes a important bug in read_spikeglx()
/ read_imro()
that was
leading to wrong contact locations when the Imec Readout Table (aka imRo) was set with complex multi-bank patterns.
The bug was introduced with version 0.2.10, released on September 1st 2022, and it is also present in these
versions: 0.2.10, 0.2.11, 0.2.12, and 0.2.13.
If you used spikeinterface/probeinterface with SpikeGLX data using one of these versions, we recommend you
to check your contact positions (if they are non-standard - using the probe tip) and re-run your spike-sorting
analysis if they are wrong.
- Other changes/bug fix:
Remove waveform_extractor.recording form template_tools (#1031)
Fix nbefore parsing in InjectTemplatesRecording (#1032)
Use parent recording dtype for InjectTemplates (#1033)